HOLMARC OPTO-MECHATRONICS LTD

Ernakulam, India gst GST No.32AAACH9492C1ZQ

Analytical Instruments

(9 products available)
HO-SPE-3000S Spectrophotometer
  • HO-SPE-3000S Spectrophotometer

HO-SPE-3000S Spectrophotometer

Minimum Order Quantity : 1 Pieces

Delivery Time : 30-45 Days

Usage Research Institute, Educational Institute & Industrial

Product Type HO-SPE-3000S Spectrophotometer

Material Metal

Color Black-Blue

Application Laboratory

Supply Ability 10 Per Month

Payment Terms Cash Advance (CA)

Main Domestic Market All India

About this product

The HO-SPE-3000S Spectrophotometer is a powerful and reliable tool for laboratory and research use. It is designed to measure the optical properties of materials, such as absorbance, transmittance, reflectance, and fluorescence. The device is constructed from durable metal for maximum stability and accuracy. It is available in a sleek black-blue color that is sure to look great in any laboratory or research setting. The device is suitable for use in research institutes, educational institutes, and industrial applications. The HO-SPE-3000S Spectrophotometer is a high-precision instrument that is capable of measuring a wide range of optical properties. It features advanced optics and a sensitive detector for accurate readings. The device has a user-friendly interface and is easy to use. It also includes a range of useful accessories, such as a sample holder, cuvette holder, and a power cord. The HO-SPE-3000S Spectrophotometer is manufactured by a reliable and experienced supplier. The device is tested for accuracy and reliability before it is shipped to ensure that you get the best performance. The manufacturer also provides excellent customer service and technical support to ensure that you get the most out of your device.

FAQs of HO-SPE-3000S Spectrophotometer:


Q: What materials is the HO-SPE-3000S Spectrophotometer made from?

A: The HO-SPE-3000S Spectrophotometer is constructed from durable metal for maximum stability and accuracy.

Q: What color is the HO-SPE-3000S Spectrophotometer?

A: The device is available in a sleek black-blue color.

Q: What type of applications is the HO-SPE-3000S Spectrophotometer suitable for?

A: The device is suitable for use in research institutes, educational institutes, and industrial applications.

Q: What type of accuracy can I expect from the HO-SPE-3000S Spectrophotometer?

A: The device is capable of providing highly accurate readings due to its advanced optics and sensitive detector.

Q: Does the HO-SPE-3000S Spectrophotometer come with any accessories?

A: Yes, the device includes a range of useful accessories, such as a sample holder, cuvette holder, and a power cord.

Q: Who manufactures the HO-SPE-3000S Spectrophotometer?

A: The device is manufactured by a reliable and experienced supplier.

Get a Price/QuoteRequest To Call Back
HO-SP-NV16 CCD Spectrophotometer
  • HO-SP-NV16 CCD Spectrophotometer

HO-SP-NV16 CCD Spectrophotometer

Minimum Order Quantity : 1 Pieces

Delivery Time : 30-45 Days

Usage Research Institute, Educational Institute & Industrial

Product Type HO-SP-NV16 CCD Spectrophotometer

Material Metal

Color Black

Application Laboratory

Supply Ability 10 Per Month

Payment Terms Cash Advance (CA)

Main Domestic Market All India

About this product

The HO-SP-NV16 CCD Spectrophotometer is a professional grade spectrometer designed for use in research institutes, educational institutes, and industrial laboratories. It is made from high quality metal and is designed for long-term use. The device is capable of measuring the intensity of light in the visible spectrum, allowing for precise color measurements. The device is equipped with a CCD camera which is capable of capturing the light spectrum in high resolution. The data obtained can be used to accurately measure the color of any sample, allowing for precise color matching. The device is also capable of measuring the intensity of light in the ultraviolet and infrared spectrum, allowing for accurate measurements of any sample. The device is easy to use and can be operated with minimal training. The device is also equipped with a variety of software features such as data storage, data analysis, and calibration. The device is also equipped with a USB port, allowing for easy data transfer. The device is designed for maximum accuracy and reliability. It is designed to withstand harsh laboratory environments and is backed by a manufacturers warranty. The device is also designed to be easy to maintain and service, allowing for long-term use.

FAQs of HO-SP-NV16 CCD Spectrophotometer:


Q: What type of material is the HO-SP-NV16 CCD Spectrophotometer made from?

A: The HO-SP-NV16 CCD Spectrophotometer is made from high quality metal.

Q: What type of data can be measured with the device?

A: The device is capable of measuring the intensity of light in the visible spectrum, allowing for precise color measurements. The device is also capable of measuring the intensity of light in the ultraviolet and infrared spectrum, allowing for accurate measurements of any sample.

Q: Is the device easy to use?

A: Yes, the device is easy to use and can be operated with minimal training.

Q: Does the device come with a warranty?

A: Yes, the device is backed by a manufacturers warranty.

Get a Price/QuoteRequest To Call Back
UV2-1911D Double Beam Dual Detector Spectrophotometer
  • UV2-1911D Double Beam Dual Detector Spectrophotometer

UV2-1911D Double Beam Dual Detector Spectrophotometer

Minimum Order Quantity : 1 Pieces

Delivery Time : 30-45 Days

Voltage 230 Volt (v)

Usage Research Institute, Educational Institute & Industrial

Product Type UV2-1911D Double Beam Dual Detector Spectrophotometer

Material Metal

Color Grey-Black

Application Laboratory

Supply Ability 10 Per Month

Payment Terms Cash Advance (CA)

Main Domestic Market All India

About this product

The UV2-1911D Double Beam Dual Detector Spectrophotometer is a reliable and advanced instrument designed for laboratory use. It has a sturdy metal construction and is available in a grey-black colour. This spectrophotometer is suitable for use in research institutes, educational institutes and industries. The UV2-1911D Double Beam Dual Detector Spectrophotometer is capable of measuring the absorption of light in the ultraviolet (UV) and visible (VIS) regions of the electromagnetic spectrum. It is equipped with a double beam design, which allows simultaneous measurements of two wavelengths for greater accuracy and precision. The instrument is also equipped with a dual detector system, which improves the sensitivity and accuracy of the measurements. The UV2-1911D Double Beam Dual Detector Spectrophotometer is easy to operate and comes with a user-friendly control panel. It has a wide range of features, including a wide variety of data storage options, a real-time graphical display of the measurements, and a range of software functions. The instrument is powered by a 230 Volt power supply and is compatible with a variety of PC systems. The UV2-1911D Double Beam Dual Detector Spectrophotometer is a reliable and advanced instrument designed for laboratory use. It is manufactured by a reliable manufacturer and supplier and is available at a competitive price.

FAQs of UV2-1911D Double Beam Dual Detector Spectrophotometer:


Q: What is the wavelength range of the UV2-1911D Double Beam Dual Detector Spectrophotometer?

A: The UV2-1911D Double Beam Dual Detector Spectrophotometer is capable of measuring the absorption of light in the ultraviolet (UV) and visible (VIS) regions of the electromagnetic spectrum.

Q: Does the UV2-1911D Double Beam Dual Detector Spectrophotometer have a dual detector system?

A: Yes, the UV2-1911D Double Beam Dual Detector Spectrophotometer is equipped with a dual detector system, which improves the sensitivity and accuracy of the measurements.

Q: What type of power supply does the UV2-1911D Double Beam Dual Detector Spectrophotometer require?

A: The UV2-1911D Double Beam Dual Detector Spectrophotometer is powered by a 230 Volt power supply.

Get a Price/QuoteRequest To Call Back
Polarimeter Holmarc
  • Polarimeter Holmarc
  • Polarimeter Holmarc

Polarimeter Holmarc

400000 INR/Piece

Minimum Order Quantity : 1 Units

Usage Laboratory, Educational, Research

Test Width 10 mm Optical Tube

Test Speed Manual

Test Range A 180A

Temperature 10A C to 40A C Operating Range

Specimen Size 100 mm & 200 mm tube length

Response Time Instantaneous

Resolution 0.05A

Power Supply 230V AC, 50 Hz

Port Size Standard Sample Tube Ports

Operating Voltage 230V AC

Number of Specimens 1

Mounting Type Benchtop

Measuring Range A 180A

Max Height 340 mm

Machine Weight 5 Kg

Humidity Up to 80% (Non-condensing)

Frequency 50 Hz

Features High sensitivity, precise optics, easy reading

Display Type Analog Scale

Control Mode Manual

Automation Grade Manual

Application Measurement of optical rotation of substances

Accuracy 0.05A

<b>Equipment Type</b> Optical Polarimeter

Payment Terms Cash in Advance (CID)

Main Export Market(s) Asia, Middle East, Africa

Main Domestic Market All India

About this product

Holmarc manufactures automatic digital polarimeters for industry and research with robust performance and efficiency. Symmetric angular oscillation optical null technique by faraday modulation is implemented in our polarimeters to achieve high resolution and repeatability. Operation is simple: place the sample filled tube in the automatic polarimeter and press read button. Measurement is displayed on the soft colour lcd display of the instrument.

The polarimeter is used for determining the optical rotation of substances. By measuring optical rotation, the concentration, content, purity etc of the sample solution can be found out. Polarimeter has become one of the most useful instruments in research laboratories of sugar industry, pharmaceutical industry, oil refining, food industry, chemical industry as well as basic research in universities and r&d organizations.

Major modules in our polarimeter include light source, interference filter, polarizer, faraday modulator, sample chamber, analyzer and detector. Unpolarized light from light source (led) passes through an interference filter and polarizer so that a fixed wavelength polarized light comes out. This polarized light enters the faraday modulator and then passes through the sample cell. The modulated light which passed through the sample cell enters a second polarizer, known as the "Analyzer, which detects the angle of rotation. Finally, the light falls on a silicon photo diode which converts the light intensity to an electric signal.



Reliable Measurement of Optical Rotation

Holmarc's Optical Polarimeter delivers high precision and dependability for analyzing optical rotation in various substances. Suitable for educational, laboratory, and research applications, the instrument employs optical glass elements and a sodium lamp at 589 nm for consistent results. The robust metal body is corrosion-proof, ensuring longevity and consistent performance.


User-Friendly Manual Operation

Equipped with a practical analog scale and manual controls, this polarimeter offers straightforward operation ideal for students and professionals alike. The double image eyepiece ensures easy and accurate alignment of readings, while the supplied calibration tube simplifies regular maintenance and accuracy checks.


Versatile and Durable Design

Constructed for versatile laboratory environments, the polarimeter operates efficiently in temperatures from 10C to 40C and humidity up to 80% (non-condensing). Its compact 5 kg benchtop form factor fits easily on standard laboratory counters, and the standard sample tube ports allow quick specimen loading.

FAQ's of Polarimeter Holmarc:


Q: How does the Holmarc Polarimeter measure optical rotation?

A: The Holmarc Polarimeter measures optical rotation using a sodium lamp (589 nm) as the light source and high-quality optical glass components. The sample tube, containing the optical substance, is placed in the device. Rotating the analyzer manually aligns the observation of double images through the eyepiece, and the resulting rotation angle is read on the analog scale.

Q: What is the process for calibrating the Holmarc Polarimeter?

A: Calibration is straightforward using the included standard calibration tube. Insert the tube, follow the manual alignment process through the eyepiece, and adjust the instrument until the scale reads zero or the prescribed calibration point, ensuring accurate and repeatable measurements.

Q: When should I use this polarimeter in my laboratory workflow?

A: This optical polarimeter is ideal whenever you need to determine the optical rotation of substances, such as sugars or optically active compounds, for quality control, research, or educational experiments. It's suitable for routine and specialized analysis.

Q: Where is this polarimeter designed to be used?

A: The Holmarc Polarimeter is built for benchtop use in laboratory, educational, and research facilities. Its compact design and sturdy construction make it well-suited for varied lab environments across India.

Q: What are the benefits of the double image observation system?

A: The double image eyepiece provides a more distinct end point when adjusting the analyzer. This enhances measurement accuracy, reduces operator fatigue, and makes optical rotation readings easier to interpret, particularly when measuring low-rotation samples.

Q: How do I use different sample tubes with this polarimeter?

A: The instrument supports 10 mm diameter tubes in either 100 mm or 200 mm lengths. Simply load your sample into the chosen tube, insert it into the standard sample port, and proceed with measurement as per the operating instructions.

Get a Price/QuoteRequest To Call Back
4 Tesla Electromagnet Lab
  • 4 Tesla Electromagnet Lab

4 Tesla Electromagnet Lab

1100000 INR/Piece

Minimum Order Quantity : 1 Units

Usage Laboratory Research

Test Width 150 mm

Test Stroke 200 mm

Test Speed 0 - 500 mm/min

Test Range 0 - 4 Tesla

Temperature 5A C - 40A C

Specimen Size Customizable (max 150 mm width)

Response Time <1 s

Resolution 0.001 Tesla

Power Supply 220V AC, 50 Hz

Port Size Standard Laboratory Interface

Operating Voltage 220V AC

Number of Specimens Up to 5

Mounting Type Bench-top

Measuring Range 0 - 4 Tesla

Max Height 450 mm

Machine Weight 140 kg

Interface Type USB, RS232

Humidity 10% - 90% RH

Frequency 50 Hz

Features High field uniformity, Low noise, Digital control

Display Type Digital LCD

Control Mode Digital Control

Capacity Max 4 Tesla field

Automation Grade Automatic

Application Material Magnetic Property Testing

Accuracy A 0.01 Tesla

<b>Equipment Type</b> Electromagnet Lab

Payment Terms Cash in Advance (CID)

Main Export Market(s) Asia, Middle East, Africa

Main Domestic Market All India

About this product

EM7000S is a HOLMARC New Magnet LAB range high magnetic field PC controlled Dipole Electromagnet that can provide fields above 3.5 Tesla @5mm field gap. Designed to meet industrial, educational, and research needs of very high, uniform field strengths in a wide range of air gaps. The HOLMARC Magnet LAB range dipole electromagnet systems are intended to work based on automated PC controlled operations.

The EM7000S comes with a standard set of 125mm diameter poles that tapered into a 25mm. optimize maximum field but several pole options are available. HOLMARC can also design custom poles that achieve a specific performance. Poles are interchangeable and are available with an axial access bore.



Advanced High Field Strength

Engineered to reach up to 4 Tesla, the lab-grade electromagnet ensures accurate and consistent magnetic field application. Its high-grade soft iron core delivers exceptional field uniformity, enabling precise measurements for demanding research and testing environments.


User-Friendly Digital Control

The system offers both manual and automatic field control modes with quick response times of under one second. Digital LCD readouts display real-time field data, simplifying operation. Programmable via USB and RS232 interfaces, it accommodates modern laboratory workflows efficiently.


Comprehensive Safety and Compliance

Equipped with automatic overload and overheat protection, the electromagnet lab meets rigorous safety standards. The forced-air cooling system maintains optimal operating conditions, ensuring long-term reliability. Certified to CE standards, it fits seamlessly into accredited labs.

FAQs of 4 Tesla Electromagnet Lab:


Q: How do I adjust the magnetic field strength with this electromagnet lab?

A: Field strength can be adjusted either manually via onboard controls or automatically through the digital interface, offering precise tuning within a range of 0 to 4 Tesla.

Q: What types and sizes of specimens can be tested using this equipment?

A: The lab supports up to five specimens simultaneously. Specimen sizes are customizable, with a maximum test width of 150 mm, accommodating a wide range of research samples.

Q: Where is the ideal environment to operate the 4 Tesla Electromagnet Lab?

A: This equipment is intended for indoor laboratory use only, within temperature limits of 5C to 40C and humidity between 10% and 90% RH, ensuring safe and optimal performance.

Q: What are the main safety features included?

A: The electromagnet features automatic overload and overheat protections, as well as forced-air cooling, safeguarding both operator and equipment during intensive testing cycles.

Q: How does the electromagnet maintain high field uniformity?

A: A high-grade soft iron core and precision pole design deliver field uniformity better than 0.1% at the center, ensuring reliable and repeatable measurements across all tests.

Q: What are the benefits of digital control and interfacing options?

A: Digital LCD display, USB, and RS232 interfaces enable easy data access, fast adjustments, and seamless integration with laboratory data systems, enhancing workflow efficiency.

Get a Price/QuoteRequest To Call Back
Spin Coating Unit
  • Spin Coating Unit
  • Spin Coating Unit
  • Spin Coating Unit

Spin Coating Unit

157000 INR/Piece

Minimum Order Quantity : 1 Units

Usage Laboratory Spin Coating

Test Width 100 mm max substrate diameter

Test Stroke Up to 150 mm (customizable)

Test Speed 500a 8000 rpm (Programmable)

Test Range Variable by spin speed and time setting

Temperature 10a 40A C (Operating environment)

Specimen Size Up to 100 mm diameter

Response Time <0.5 sec

Resolution 1 rpm

Power Supply 230 V AC, 50 Hz

Operating Voltage 230 V AC

Number of Specimens 1 (Single chuck)

Mounting Type Tabletop

Measuring Range Customizable via process parameters

Max Height 300 mm (with lid open)

Machine Weight Approx. 18 kg

Interface Type Membrane keypad with digital display

Humidity 20%a 85% RH (Operating environment)

Hardness Industrial-grade corrosion-resistant materials

Gas Pressure 0.5 ~ 1 bar for optional purge (if equipped)

Frequency 50 Hz

Features Compact design, programmable speed and time, solvent-resistant bowl, quick-release chuck

Display Type Backlit digital LCD

Control Mode Digital microprocessor based

Capacity 50 ml (standard sample cup)

Automation Grade Semi-automatic

Application Coating thin films on substrates, photoresist application

Accuracy A 10 rpm

<b>Equipment Type</b> Bench-top Spin Coating Unit

Payment Terms Cash in Advance (CID)

Main Export Market(s) Africa, Middle East, Asia

Main Domestic Market All India

About this product

Holmarcs Spin Coating unit, Model no: HO-TH-05C has been designed with many additional features than that of Model: HO-TH-05.

In this model of spin coater, UV LED curing system is used whenever there is a need for curing and drying of coatings. It also provides gases purge facility for additional supply of gases inside the chamber. Vaccum Chucks provide flat, rigid surface for mounting substrates of different sizes and shapes. A vaccum chuck powered by oil- less vaccum pump holds the substrate at the spinning head. In-built sample dispensing system (optional accessory) helps to supply volatile solution in milli liter volume. The syringe holder height can be adjusted and rotated freely along the support rod. All required safety measures are provided for high speed rotation and spillage. It also provides facility for drainage.

The system has a user friendly front panel with key board and LCD display. The programs are easy to set up with up to 9 steps per program. All other features are same as that of Model: HO-TH-05. Three sets of nylon anti-corrosive vacuum chucks are provided along with the equipment for holding substrate from 15 x 15 mm square to 100 x 100 mm square.



Precision and Programmable Coating

With a digital microprocessor, users can set spin speeds from 500 to 8000 rpm and time durations between 1 and 999 seconds. This programmability allows for highly precise and repeatable film coatings suitable for research and development of photoresists, polymers, and sol-gel materials.


Designed for Safe and Efficient Operation

Safety is prioritized with a transparent interlocked lid, over-speed, and imbalance protections. The removable Teflon-coated bowl allows quick cleaning and reduces contamination risks, while a noise level below 55 dB ensures a comfortable working environment in laboratory settings.


Versatile Compatibility and User-Friendly Interface

Accommodating various consumables, this unit easily coats substrates up to 100 mm in diameter. The membrane keypad and backlit digital LCD provide straightforward operation and real-time process monitoring. Adaptable gas purge allows for humidity-sensitive coatings when equipped.

FAQ's of Spin Coating Unit:


Q: How do I operate the Spin Coating Unit for thin film deposition?

A: To operate, place your substrate (up to 100 mm diameter) on the vacuum chuck, select desired speed and time on the digital microprocessor interface, close the transparent lid, and start the process. The programmable controls ensure accurate and repeatable spin coating results.

Q: What materials and consumables are compatible with this spin coater?

A: The unit is compatible with photoresists, sol-gel solutions, polymers, and more. Its solvent-resistant Teflon-coated bowl and stainless steel construction provide robust protection against chemical corrosion, ensuring longevity during frequent usage with various solutions.

Q: When should the removable bowl be cleaned, and how is it maintained?

A: It is advisable to clean the bowl after every coating session, especially when switching between different materials, to prevent cross-contamination. Simply remove the bowl, rinse with an appropriate solvent, and dry thoroughly before reinstalling.

Q: Where can this spin coater be installed and used effectively?

A: The bench-top design makes it ideal for laboratories, research institutes, university labs, and production environments in India or similar operating conditions. Its compact footprint allows easy placement on standard laboratory tables, ensuring efficient use of space.

Q: What safety features protect users during operation of the unit?

A: The equipment includes a transparent polycarbonate lid with safety interlock, over-speed and imbalance protections, ensuring that spin operations cannot proceed if unsafe conditions are detected, thereby safeguarding users during operation.

Q: How does programmable control benefit the coating process?

A: Programmable speed and time settings allow for tailored process parameters, enhancing coating uniformity and reproducibility. Quick adjustments via the membrane keypad and real-time feedback on the digital LCD improve process efficiency and versatility for diverse applications.

Get a Price/QuoteRequest To Call Back
Reflectometer Holmarc
  • Reflectometer Holmarc

Reflectometer Holmarc

388000 INR/Piece

Minimum Order Quantity : 1 Units

Usage Laboratory, industrial

Test Width Up to 100 mm

Test Stroke 0 - 50 mm

Test Speed Variable, 1 - 100 mm/min

Test Range Reflectance 0 - 100%

Temperature Ambient, 10A C - 40A C

Specimen Size 15 mm to 100 mm diameter

Response Time <1 second

Resolution 0.01%

Power Supply 230V AC, 50 Hz

Port Size Standard 2 optical port

Operating Voltage 230V AC

Number of Specimens Single specimen per test

Mounting Type Bench-top

Measuring Range 0 - 100% reflectance

Max Height 150 mm

Machine Weight 25 kg

Interface Type USB, RS232

Humidity Up to 80% RH

Frequency 50 Hz

Features High precision, software data acquisition

Display Type Digital LCD

Control Mode Manual / Automatic

Capacity Up to 2 kg sample holder

Automation Grade Semi-automatic

Application Measurement of reflectance of coated/uncoated surfaces

Accuracy A 1%

<b>Equipment Type</b> Reflectometer

Payment Terms Cash in Advance (CID), Cash in Advance (CID)

Main Export Market(s) Asia, Middle East, Africa

Main Domestic Market All India, All India

About this product

Thin film spectroscopic reflectometer is a fundamental instrument used for the analysis of thin film thickness in industry and research. Holmarcs tfsr model is able to analyze thin films thickness, complex refractive index and surface roughness with high speed and repeatability. Tfsr theory works with complex matrix form of fresnel equations for reflectance and transmittance. Absolute reflectance spectroscopy is the principle behind reflectometer; which is the ratio of the intensity of the reflected light beam (usually monochromatic) to the intensity of the incident beam.

Light beam normally incident on the sample surface in turn reflect from top and bottom of the thin film surfaces which get interfered and is directed through optical fiber to ccd attached spectrometer via computer. On the monitor we get spectrogram with interference oscillations directly proportional to the thin film thickness.

Holmarcs reflectometer can be used to analyze single, multi-layer, free standing and rough layer thickness of various stacks such as di-electric, crystalline, amorphous, metallic and absorbing samples. It also finds absolute transmittance and absorption directly. Roughness treatment is done with ema modeling. The instrument can also be used to find optical conductivity, molar refractivity and brewsters angle of sample under study.



Advanced Reflectance Measurement

The Holmarc Reflectometer features a halogen lamp with a collimated beam for precise and reproducible reflectance measurements from 400 nm to 700 nm. The photodiode array detector ensures high accuracy and rapid response, making the system suitable for analysis of a wide range of coated and uncoated surfaces in laboratory environments.


User-Friendly Operation and Versatility

With adjustable test speeds, sample holders catering to specimens from 15 mm up to 100 mm in diameter, and the capacity to measure a single specimen weighing up to 2 kg, the instrument provides remarkable flexibility. Software compatibility with Windows systems and multiple interface options (USB, RS232) streamline data acquisition and documentation.


Enhanced Safety and Reliable Performance

Protective measures like fuse and overvoltage safeguards ensure safe operation, while standard mirror calibration maintains consistent accuracy (1%). The anti-slip specimen holder enhances measurement stability. Data can be exported in both graphical and tabular formats, enhancing analytical efficiency during laboratory and industrial use.

FAQ's of Reflectometer Holmarc:


Q: How does the Reflectometer Holmarc ensure accurate reflectance measurements?

A: The Reflectometer employs a standard mirror calibration procedure and features a photodiode array detector for precise, consistent readings within the 0 - 100% reflectance range. This setup, combined with its collimated halogen light source, supports high accuracy (1%) and excellent resolution (0.01%).

Q: What types of surfaces can be analyzed using this reflectometer?

A: This instrument is suitable for measuring the reflectance of both coated and uncoated surfaces. The adjustable sample holder accommodates specimens with diameters from 15 mm to 100 mm, making it versatile for various material types and thicknesses.

Q: When should mirror calibration be performed on the device?

A: Mirror calibration is recommended before starting a new measurement series or when the system settings are changed, to ensure ongoing accuracy and reliability of reflectance data.

Q: Where is the ideal environment to operate the Reflectometer Holmarc?

A: The device is best operated in laboratory conditions with ambient temperatures between 10C and 40C, and humidity up to 80% RH. Stable bench-top mounting and a clean, vibration-free workspace also support optimal performance.

Q: What is the process for acquiring and exporting reflectance data?

A: After positioning the specimen and configuring settings via the digital LCD, measurements are initiated in manual or automatic mode. Data is displayed in real-time and can be exported directly in graphical and tabular formats for analysis or reporting.

Q: How does the reflectometer benefit users in laboratory or industrial settings?

A: Users benefit from its fast response (<1 second), high measurement accuracy, and ease of use. Its robust safety features and software compatibility enable secure, efficient data handling for research, quality control, or production applications.

Get a Price/QuoteRequest To Call Back
UV Ozone Cleaner
  • UV Ozone Cleaner
  • UV Ozone Cleaner
  • UV Ozone Cleaner

UV Ozone Cleaner

105000 INR/Piece

Minimum Order Quantity : 1 Volts

Usage Laboratory, Research, Industrial

Test Width 200 mm

Test Range Surface Cleaning

Temperature 5A C-40A C

Specimen Size Max. 200 x 200 mm

Response Time Immediate

Power Supply AC 220V, 50/60Hz

Port Size Standard 1/4 inch NPT

Operating Voltage 220V AC

Number of Specimens 1

Mounting Type Bench-top

Max Height Approx. 300 mm

Machine Weight Approx. 12 kg

Interface Type Start/Stop Switch

Humidity 20-80% RH (non-condensing)

Gas Pressure Atmospheric

Frequency 50/60 Hz

Features Stainless steel chamber, Safety interlock, Low maintenance, UV-resistant window, Programmable timer

Display Type Digital Timer Display

Control Mode Manual & Automatic

Automation Grade Semi-Automatic

Application Surface cleaning, Organic contamination removal, Pre-treatment for semiconductors and substrates

<b>Equipment Type</b> UV Ozone Cleaner

Main Export Market(s) Asia, Middle East, Africa

Main Domestic Market All India

About this product

Holmarc's UV Ozone Cleaner is a dedicated system to remove a variety of contaminants from surfaces of substrates samples. UV Ozone cleaning is a simple to use dry process which is highly effective method to clean surfaces. The cleaning effect is caused by irradiating the surface of a substrate with suitable lamps creating enough energy in the in the Ultra Violet spectrum range. It is photo-sensitized oxidation process by atomized Oxygen and high reactive Ozone. The UV radiation directly to the surface stimulates the reaction. Volatile hydrocarbon products are produced. The removal of hydrocarbons in nanometer thickness by oxidation results in ultra clean surfaces with significantly wettability. This is very important before thin film coating process of glass and ceramic surfaces.

UV Ozone Cleaner features very high ozone UV lamps which generate energy at 185 nanometers in addition to the low 254 nm line. It provides a trey of 176mm x 168 mm dimension for positioning samples under the UV light source. It comes with an exhaust port and inlet media for the circulation of gas in the trey. Emergency stop is also provided on the control panel to stop the equipment where there is any emergency.



Efficient and Versatile Surface Cleaning

The UV Ozone Cleaner harnesses the power of a 15W UV-C lamp to generate ozone for effective surface cleaning and organic contaminant removal. Its robust stainless steel 304 chamber ensures durability, while programmable settings offer flexibility for various laboratory and industrial tasks. This machine is especially suited for semiconductor and substrate pre-treatment, delivering reliable, fast results every time.


Advanced Safety and User-Friendly Operation

Safety is built into every facet of the UV Ozone Cleaner, with a door interlock, visible power and operation status LEDs, and overheat protection. Its integrated exhaust fan safely evacuates ozone, ensuring a secure work environment. Operation is simple with manual and automatic controls and a digital timer, making it accessible to both seasoned professionals and new users.

FAQ's of UV Ozone Cleaner:


Q: How does the UV Ozone Cleaner remove organic contaminants from surfaces?

A: The UV Ozone Cleaner utilizes a 15W UV-C lamp that emits light at 254 nm, generating ozone within a stainless steel chamber. The combination of UV-C radiation and ozone effectively breaks down and oxidizes organic contaminants on surfaces, leaving them clean and residue-free.

Q: What types of applications is this UV Ozone Cleaner suitable for?

A: This equipment is ideal for laboratory, research, and industrial applications, especially for cleaning and pre-treating surfaces in semiconductors, substrates, and other sensitive components where organic contaminant removal and surface energy modification are required.

Q: When should the ozone exhaust fan be used during cleaning operations?

A: The integrated exhaust fan operates during and after the cleaning process to safely ventilate ozone from the chamber, ensuring that no harmful gases escape into the surrounding environment. It is automatically engaged according to safety protocols and should always be used as indicated.

Q: Where should the UV Ozone Cleaner be installed for optimum operation?

A: Install the UV Ozone Cleaner on a stable bench-top surface in a laboratory or industrial workspace with an ambient temperature between 5C and 40C and non-condensing humidity of 20-80%. Ensure proper electrical connections and adequate ventilation around the unit for safe operation.

Q: What is the recommended process for using the UV Ozone Cleaner?

A: Place the specimen (up to 200 x 200 mm) inside the chamber, close the door securely, set the timer (up to 99 minutes), and select manual or automatic mode. Start the cycle using the Start/Stop switch. The machine will then expose the specimen to UV-C light and generated ozone, followed by ventilation once the cycle completes.

Q: How do the safety features protect operators during use?

A: The UV Ozone Cleaner is equipped with a door interlock to prevent operation when the door is open, overheat protection to safeguard internal components, and visible indicators to show power and operational status, ensuring maximum safety for operators at all times.

Q: What are the benefits of using a stainless steel chamber in the UV Ozone Cleaner?

A: The stainless steel 304 chamber offers superior chemical resistance, durability, and easy maintenance, while also ensuring a contaminant-free environment for precise surface cleaning and treatment.

Get a Price/QuoteRequest To Call Back
Syringe Pump Holmarc
  • Syringe Pump Holmarc
  • Syringe Pump Holmarc
  • Syringe Pump Holmarc

Syringe Pump Holmarc

132000 INR/Piece

Minimum Order Quantity : 1 Units

Usage Liquid dispensing for labs

Test Width 150 mm

Test Stroke 100 mm

Test Speed 0.001 to 50 mm/min (programmable)

Test Range Programmable syringe dispense volume

Temperature 5A C to 40A C operating range

Specimen Size 10 ml to 60 ml syringe capacity

Response Time Immediate (microcontroller)

Resolution 0.001 ml

Power Supply 230V AC, 50/60Hz

Port Size Compatible with standard syringes (up to 60 ml)

Operating Voltage 230V AC

Number of Specimens Up to 2 syringes

Mounting Type Bench-top

Measuring Range 0.001 ml to 60 ml

Max Height 220 mm (with syringe installed)

Machine Weight 4.5 kg

Interface Type RS232, USB

Humidity 10-90% RH (non-condensing)

Frequency 50/60 Hz

Features Programmable flow rate, continuous and step dispensing, backward/forward operation

Display Type LCD Digital Display

Control Mode Microcontroller Based

Capacity Max. 60 ml syringe

Automation Grade Semi-Automatic

Application Precise liquid handling and dispensing

Accuracy A 1% of set volume

<b>Equipment Type</b> Programmable Syringe Pump

Payment Terms Cash in Advance (CID)

Main Export Market(s) Africa, Middle East, Asia

Main Domestic Market All India

About this product

A syringe pump is a device which can either infuse or withdraw liquid samples/fluids, at user defined flow rates and with selectable target volumes. Syringe pumps with simultaneous infusion and withdrawal with opposing syringes on a single drive, are also available.


Syringe pumps are widely used in medical field as well as in laboratory and research fields.

Applications of syringe pumps includes electro spinning, electro spraying, micro dialysis, dispensing/dilution, organ/tissue perfusion and fluid circulation.

Syringe pumps are also useful in microfluidic applications, such as micro reactor design and testing, and in chemistry for slow incorporation of a fixed volume of fluid into a solution.

Model: SPLF Series

Holmarc's SPLF series syringe pumps are versatile products ideal for precise dispensing of fluids in laboratory experiments, available at an economical price. Our bench-top Syringe Pump has been designed for safe and ultra-smooth fluid flow for lab applications and can be easily set up inside a standard fume cupboard. Holmarc manufactures syringe pumps in various models for single syringes, two syringes, four syringes and ten syringes.




Versatile and Precise Dispensing Solution

Holmarc's Syringe Pump is engineered for laboratories requiring accurate, controlled dispensing of liquids. Its wide compatibility with standard syringes and programmable dispense volumes make it ideal for applications such as titrations, reagent addition, and sample introduction. The microcontroller-based control mode ensures immediate response times and seamless programming of test parameters.


Key Safety and Usability Features

Safety is prioritized with built-in overload protection and an emergency stop function, providing peace of mind during operation. The LCD digital display presents real-time volume measurements at a high resolution of 0.001 ml, ensuring operators can monitor progress accurately. The bench-top design and low ambient noise (<55 dB) further enhance ease of use in busy lab environments.

FAQ's of Syringe Pump Holmarc:


Q: How does the Holmarc Syringe Pump ensure precise liquid dispensing?

A: The pump employs a stepper motor-driven lead screw mechanism, guaranteeing consistent motion and accurate dispensing. With programmable flow rates from 0.01 to 120 ml/min and a display resolution of 0.001 ml, the system achieves high precision, maintaining an accuracy of 1% of the set volume.

Q: What types of syringes can be used with this syringe pump?

A: The Holmarc Syringe Pump is compatible with both plastic and glass syringes ranging from 10 ml to 60 ml in capacity, accommodating sizes commonly used in laboratory settings.

Q: When should the emergency stop function be used?

A: The emergency stop feature should be activated immediately if any abnormal operation, overload, or unsafe condition occurs during dispensing. It ensures operator safety by halting all functions instantly.

Q: Where can the syringe pump be installed for optimal use?

A: Designed as a bench-top unit, the syringe pump can be conveniently placed on laboratory workstations. It operates reliably in ambient conditions from 5C to 40C with humidity between 10-90% RH (non-condensing).

Q: What is the process for upgrading the pump's firmware?

A: Firmware upgrades can be performed via the provided USB or RS232 interface. Follow the manufacturer's instructions to connect the device to a computer and execute the upgrade process, ensuring your pump benefits from the latest features and updates.

Q: How does the programmable control enhance usage?

A: The microcontroller-based system allows for direct programming of dispensing volume, flow rate, and test speed, enabling repeatable, hands-free operation. This automation reduces manual error and increases throughput in liquid dispensing tasks.

Q: What are the main benefits of using the Holmarc Syringe Pump in laboratories?

A: This syringe pump offers consistent accuracy, flexible programmability, and enhanced operator safety features. Its semi-automatic operation streamlines liquid dispensing, making it an excellent solution for precise laboratory workflows.

Get a Price/QuoteRequest To Call Back

Contact Us

Message